Description

We already discussed about displaying system info, now I remember what was the real problem annoying me:

-after a few seconds of displaying system info (doesn't matter which category) all information in user interface get overwritten by "busy"
It would be a great improvement to NOT show "busy" but instead let the old value printed until a new value will be set.


Related issues 1 (0 open1 closed)

related to Bug #321: system info: hardcoded values get resetClosedbuzz20/09/2014

Actions
Actions #1

Updated by buzz about 10 years ago

  • Status changed from New to Feedback
  • Assignee set to tim619
  • Priority changed from Normal to Low

Feel free to provide a patchset - not sure this is something important enough to spend any time on personally :)

Actions #2

Updated by buzz about 10 years ago

  • Status changed from Feedback to Closed
  • Assignee changed from tim619 to buzz
  • % Done changed from 0 to 100
  • Resolution set to fixed

fixed in r32970

Actions #3

Updated by buzz about 10 years ago

  • related to Bug #321: system info: hardcoded values get reset added
Actions #4

Updated by tim619 about 10 years ago

I think it is not fixed. There is no visual difference to previous builds (tested on r32972).

Here screens:
(screenshot002 to show no difference, screenshot007 and screenshot008 show differnces if values resetted. Note: i.e. Temperature values are set new without showing busy, that's exactly what I wanted.)

http://abload.de/img/screenshot002xzqf5.png
http://abload.de/img/screenshot003m6oy6.png
http://abload.de/img/screenshot004pnpmb.png
http://abload.de/img/screenshot005kgpuc.png
http://abload.de/img/screenshot006v5o4x.png
http://abload.de/img/screenshot007l2o9z.png
http://abload.de/img/screenshot008r8qos.png

Actions #5

Updated by tim619 about 10 years ago

After testing again I cant reproduce and it really seems fixed. I rebooted and seems fixed again. I'm wondering why on the first start it renewed ervery 15 seconds and now works...
I tried with and without internet connection both works now...

Actions #6

Updated by buzz about 10 years ago

if the jobs take longer than a second to process, it will still show busy momentarilly. it;s to do with the infoloader and the way the job manager works while it waits for values. so if the internet test (which is the only thing that takes time). doesnt complete in time it still might show busy,. I may increase the delay some more. if the job finishes in under a second, no busy values are shown.